CFYFY - SODER-WICK FINE-BRAID, PC:SERIES 50,80,90
- MSDS: CFYFY
- Manufacturer: CHEMTRONICS INC
- Product Name: SODER-WICK FINE-BRAID, PC:SERIES 50,80,90
- National Stock Number: 3439-01-198-9415
Product Identification
Product ID:SODER-WICK FINE-BRAID, PC:SERIES 50,80,90
MSDS Date:01/26/1996
FSC:3439
NIIN:01-198-9415
MSDS Number: CFYFY
Responsible Party
KENNESAW, GA 30144
US
Emergency Phone: 770-424-4888/800-424-9300(CHEMTREC)
Info Phone: 800-645-5244/800-TECH-401
Preparer: GWEN CONWELL
Cage: 2M589
Contractor
Telephone: 770-424-4888/800-645-5244
Cage: 2M589
Ingredients
COPPER (SARA 313) (CERCLA)
CAS: 7440-50-8
RTECS: GL5325000
Fraction By Weight: 90-98%
OSHA PEL 0.1MG/M3 FUME/1 DUST
ACGIH TLV: 0.2 MG/M3 FUME; 9596
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ROSIN ACID
CAS: 8050-09-7
Fraction By Weight: 2-10%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE/INHAL:NO EFFECT EXPECTED UNDER
NORMAL CONDITIONS OF USE.VAP RELEASED FRM OTHER MATLS USED IN
DESOLDERING PROCESS MAY CAUSE IRRIT EYE/MOUTH/NOSE/THROAT.SKIN:PROL
CONTACT MAY CAUSE IRRIT.INGEST:HARM FUL IF INGEST.METAL CONTACT MAY
BE IRRIT MOUTH/THROAT/STOMACH TISSUES.INHAL:DUST/FUMES DURING
DESOLDERING IRRIT (SUPPLE)
Explanation of Carcinogenicity:PER MSDS:CANCER INFORMATION:NO INGREDS
LISTED AS HUMAN CARCINOGEN BY NTP/IARC.
Effects of Overexposure:VAP RELEASED FRM OTHER MATLS USED IN
DESOLDERING PROCESS MAY CAUSE EYE IRRIT & IRRIT MOUTH/NOSE/THROAT.
SKIN IRRIT, HARMFUL IF SWALLOWED, IRRIT MOUTH/THROAT/STOMACH
TISSUES.
Medical Cond Aggravated by Exposure:NONE KNOWN.
First Aid
First Aid:EYE:USUALLY NOT REQUIRE.IRRIT OCCUR IMMED FLUSH W/LOTS OF
H2O.AT INITIAL FLUSH REMOVE ANY CONTACT LENSES,CONT FLUSH @LEAST
15MINS.IRRIT DEVLPS/PERSIST HAVE EYES EXAMINE/TEST BY MED
PERSON.SKIN:USUALLY NOT REQUIRE.IRRIT OCCUR WASH W/SOAP/H2O.REMOVE
CONTAM CLOTH.IRRIT DEVLPS/PERSIST GET MEDA TTN.INGEST:DONT INDUCE
VOMIT.GET IMMED MED ATTN.INHAL:OVERCOME BY FUMES DURING DESOLDERING
PROCESS (SUPPLEM)
Fire Fighting
Flash Point:NON-FLAMMABLE
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:WATER FOG,CO2,DRY CHEMICAL,FOAM ARE COMPATIBLE FOR
EXTINGUISHING FIRES INVOLVING OTHER MATL WHEN SOLDER-WICK IS
PRESENT.
Fire Fighting Procedures:AS IN ANY FIRE WEAR SELF-CONTAINED BREATHING
APPARATUS (PRESSURE-DEMAND, MSHA/NIOSH APROV/EQUIVALENT)& FIRE
PROTETIVE GEAR.
Unusual Fire/Explosion Hazard:NON-FLAMMABLE.
Accidental Release
Spill Release Procedures:PICK UP SPILLED BRAID.IF SOILED OR DIRTY STORE
IN CLOSED CNTNR FOR DELIVERY TO METALS RECYCLING CENTER.DONT
DISPOSE OF BY PLACING IN TRASH.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID PROL/REP COTNACT W/EYE/SKIN.USE
W/ADEQUATE VENTILATION.AVOID BREATH VAP GIVEN OFF BY DESOLDERING
PROCESS.STORE IN COOL DRY PLACE.
Other Precautions:KEEP CNTNR CLSD WHEN NOT IN USE.KEEP OUT OF REACH OF
CHILDREN. CONTAINS COPPER,CHEM SUBJ TO SEC 313 EPCRA/40CFR372.PROD
SHOULD BE USED ONLY W/ADE VENTI TO QUICKLY DISPERSE VAP FRM
DESOLDER.MECH VENTI USED W/LG FUME PRODUCE.
Exposure Controls
Respiratory Protection:WEAR +PRESSURE AIR-SUPPL RESP IN SITUATIONS
WHERE THERE MAY BE POTENTIAL FOR AIRBORNE EXPO.THIS MATL & DESOLDER
PROCESS DOESNT HAVE ESTABLISHED EXPO LIMITS.VENTI NOT AVAI WEAR
NOSH APPROV ORGANIC VAP RESP W/PART DUST FILT FOR WELD/SOLDER.
Ventilation:GOOD GEN VENTI SHOLD BE SUFFIC TO CNTRL AIRBORNE LEVELS OF
DESOLDERING PROCESS VAP.LOC EXHAU VENTI MAY BE NECESSARY(SUP)
Protective Gloves:NONE SPECIFIED BY MANUFACTURER.
Eye Protection:SAFTEY GLASSES W/SIDE SHIELD,GOGG
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH CONTAM CLOTH BEF REUSE.WASH HANDS BEFORE
EATING.
Supplemental Safety and Health
HEALTH:RESP TRACT.LONG-TERM FUME OVEREXPO CAN LEAD TO LEAD
POISONING.INGEST/SKIN:CAN CAUSE ALLERGIC RX IN SOME
PEOPLE.EYE:CONTACT W/ROSIN DUST/DESOLD FUME IRRIT. 1STAID:REMOVE
VICTIM TO FRESH AIR.NOT BREATH GIVE ART RESP;BREATH DIFFI GIVE
OXY.GET MED ATTN. VENTI:TO CNTRL AIR CONTAM TO WH/IN TLV DURING USE
OF PROD.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:604F,318C
Melt/Freeze Pt:M.P/F.P Text:1083F,584C
Decomp Temp:Decomp Text:NP
Vapor Pres:100 @317F
Vapor Density:>1
Spec Gravity:8.92
pH:NA
Viscosity:NA
Evaporation Rate & Reference:>1, BUTYL ACETATE=1
Solubility in Water:INSOLUBLE
Appearance and Odor:SHINY,BRAID CU WIRE;ROSIN COATED BRAID CU
WIRE,SHARP,METALLIC ODOR,CU METAL COL
Percent Volatiles by Volume:NA
Corrosion Rate:NP
Stability
Stability Indicator/Materials to Avoid:YES
DO NOT MIX W/POWDERED ALKALI AND ALKALINE EARTH METALS OR STRONG
OXIDIZING AGENTS.
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE.
Disposal
Waste Disposal Methods:AVOID RUNOFF INTO STORM SEWERS/DITCHES WHICH
LEAD TO H2OWAYS.H2O RUNOFF OF DESOLDERING PROCESS RESIDUES MAY
CAUSE ENVIRO DMG.US REGS REQUIRE REPORT SPILL OF THIS MATL THAT
COULD REACH SURF H2O.US COAS T GUARD NFC 800-424-8802.DISPO IAW
FED/STA/LOC REG
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.